inquiry
Leave Your Message
Products Categories
Featured Products

2M detection distance M30 analog output 0-10V/4-20mA ultrasonic distance sensor switch for UC2000-F42

The UC2000-F42 ultrasonic proximity switch is a high-performance non-contact detection device that uses the ultrasonic pulse reflection principle. It can accurately detect solids, liquids, powders, and transparent objects, with a detection range covering several centimeters to several meters, a small blind zone, and an accuracy of up to millimeter level. It features temperature compensation and operates in environments from -25°C to 70°C, with a protection rating of IP54 or higher, resistant to dust and oil contamination. The device supports analog output (such as 4-20mA) and switch output, with a repeatability of ≤0.1% of full scale. It is suitable for harsh industrial scenarios such as metallurgy, logistics, and packaging machinery, meeting high-precision and high-reliability detection requirements, making it an ideal choice in the field of industrial automation.

    Working Principle

    The ultrasonic proximity switch's transmitter emits high-frequency ultrasonic waves. When these waves encounter an object, they are reflected back. The receiver captures the reflected echoes, and by measuring the time it takes for the ultrasonic waves to travel from transmission to reception, and combining this with the propagation speed of ultrasound in air, the distance between the sensor and the object can be calculated. When the distance reaches a preset threshold, the switch outputs the corresponding signal.

    Product Features

    1.Multiple signal outputs  
    2.Non-contact detection  
    3.Strong environmental adaptability  
    4.Wide detection range  
    5.Unaffected by material

    Product detail

    UC500-F42 (1)UB500-18GM75- (2)ESMUS07- (3)

    Technical Specifications

    Product model

    UC500-F42-E4-V15

    UC2000-F42-E4-V15

    UC4000-F42-E4-V15

    UC500-F42-E5-V15

    UC2000-F42-E5-V15

    UC4000-F42-E5-V15

    Detection range

    50...500mm

    80...2000mm

    200...4000mm

    Detect dead zones

    0...50mm

    0...80mm

    0...200mm

    Transducer frequency

    About 380KHZ

    About 180KHZ

    About 85KHZ

    Response time

    About 50ms

    About 150ms

    About 325ms

    Switching frequency

    ≤10HZ

    ≤3.3HZ

    ≤1.5HZ

    Output type

    E4 NPN NO/NC

    E5 PNP NO/NC

    Operating voltage

    10-30VDC ripple 10%

    Rated operating current

    200mA short-circuit protection/overload protection

    Repeatability

    ≤0.5%

    Range adjustment

    The farthest and closest ranges are adjusted by the adjustment line

    Degree of protection

    IP65

    Connection method

    V15 (5-pin) M12 cable/2m PVC cable

    LED yellow light

    The switch status indicates that the yellow light flashes and the target is detected in the set state

    LED red light

    Solid red: Error   

    Flashing red light: No target detected in the set state

    Product model

    UC500-F42-E6-V15

    UC2000-F42-E6-V15

    UC4000-F42-E6-V15

    UC500-F42-E7-V15

    UC2000-F42-E7-V15

    UC4000-F42-E7-V15

    Detection range

    50...500mm

    80...2000mm

    200...4000mm

    Detect dead zones

    0...50mm

    0...80mm

    0...200mm

    Transducer frequency

    About 380KHZ

    About 180KHZ

    About 85KHZ

    Response time

    About 21ms

    About 65ms

    About 145ms

    Switching frequency

    ≤7HZ

    ≤2.5HZ

    ≤1HZ

    Output type

    E6:Two ways PNP NO/NC

    E7:Two ways NPN NO/NC

    Operating voltage

    10-30VDC ripple 10%

    Rated operating current

    200mA short-circuit protection/overload protection

    Repeatability

    ≤0.5%

    Range adjustment

    The farthest and closest ranges are adjusted by the adjustment line

    Degree of protection

    IP65

    Connection method

    V15 (5-pin) M12 cable/2m PVC cable

    LED yellow light

    The switch status indicates that the yellow light flashes and the target is detected in the set state

    LED red light

    Solid red: Error   

    Flashing red light: No target detected in the set state

    Product model

    UC500-F42-I-V15

    UC2000-F42-I-V15

    UC4000-F42-I-V15

    UC500-F42-U-V15

    UC2000-F42-U-V15

    UC4000-F42-U-V15

    Detection range

    50...500mm

    80...2000mm

    200...4000mm

    Detect dead zones

    0...50mm

    0...80mm

    0...200mm

    Transducer frequency

    About 380KHZ

    About 180KHZ

    About 85KHZ

    Response time

    About 21ms

    About 65ms

    About 145ms

    Standard target board

    100mm*100mm

    Output type

    I:4-20mA

    U:0-10V

    Operating voltage

    10-30VDC ripple 10%

    Rated operating current

    200mA short-circuit protection/overload protection

    Repeatability

    ≤0.5%

    Range adjustment

    The farthest and closest ranges are adjusted by the adjustment line

    Degree of protection

    IP65

    Connection method

    V15 (5-pin) M12 cable/2m PVC cable

    LED yellow light

    The switch status indicates that the yellow light flashes and the target is detected in the set state

    LED red light

    Solid red: Error   

    Flashing red light: No target detected in the set state

    Wiring Definition

    This is a paragraph

    1. Black, White - Power
    2. Green - Ground
    3. Yellow - Common (COM), Blue - Normally Closed (NC), Red - Normally Open (NO)