500mm M30 Threaded Installation Ultrasonic distance sensor with 24vdc
Working Principle
The ultrasonic proximity switch's transmitter emits high-frequency ultrasonic waves. When these waves encounter an object, they are reflected back. The receiver captures the reflected echoes, and by measuring the time it takes for the ultrasonic waves to travel from transmission to reception, and combining this with the propagation speed of ultrasound in air, the distance between the sensor and the object can be calculated. When the distance reaches a preset threshold, the switch outputs the corresponding signal.
Product Features
1. Strong environmental adaptability: The metal casing usually has a protection rating of IP65/IP67, allowing stable operation in dusty, humid, or lightly oily environments.
2. Non-contact measurement: No contact with the measured object is required, avoiding mechanical wear; suitable for detecting fragile, high-temperature, or easily deformed materials.
3. Wide range coverage: The M30 ultrasonic sensor has a range of 500mm~20000mm, and some models support analog output (4-20mA/0-10V) or switch output.
4. Easy installation: The standard M30 thread can be directly screwed into the device or bracket, compatible with standard installation methods in industrial automation systems.
application scenarios
1. Liquid/Material Level Monitoring: Continuous liquid/material level measurement in water tanks and silos, with high and low level alarms.
2. Material Sorting and Positioning: Object position detection and distance measurement on automated production lines.
3. Collision Prevention and Safety Protection: Obstacle detection for AGV carts and construction machinery to prevent collisions.
4. Packaging and Logistics: Package height detection, stack height control, etc.
Product detail

Technical Specifications
|
Product model |
UB500-30GM-E4-V15 |
UB2000-30GM-E4-V15 |
UB500-30GM-E6-V15 |
UB2000-30GM-E6-V15 |
|
UB500-30GM-E5-V15 |
UB2000-30GM-E5-V15 |
UB500-30GM-E7-V15 |
UB2000-30GM-E7-V15 |
|
|
Detection range |
50...500mm |
80...2000mm |
50...500mm |
80...2000mm |
|
Detect dead zones |
0...50mm |
0...80mm |
0...50mm |
0...80mm |
|
Transducer frequency |
About 380khz |
About 180khz |
About 380khz |
About 180khz |
|
Response time |
About 50ms |
About 150ms |
About 21ms |
About 65ms |
|
Switching frequency |
≤10HZ |
≤3.3HZ |
≤7HZ |
≤2.5HZ |
|
Output type |
E4: NPN NO/NC |
E6: Two ways PNP NO/NC |
||
|
E5: PNP NO/NC |
E7: Two ways NPN NO/NC |
|||
|
Rated operating current |
200mA short-circuit protection/overload protection |
2*100mA short circuit protection/overload protection |
||
|
Repeatability |
≤0.5% |
≤0.1% |
||
|
Operating voltage |
10-30VDC ripple 10% |
|||
|
Range adjustment |
The farthest and closest ranges are adjusted by the adjustment line |
|||
|
Degree of protection |
IP65 |
|||
|
Connection method |
V15 (5-pin) M12 cable/2m PVC cable |
|||
|
LED green light |
Always-on: powered on Flashing: The target is detected in the set state |
|||
|
LED yellow light |
Solid: Switch status output Flashing:Set |
|||
|
LED red light |
Working state: Error No target detected in the setting state |
|||
|
Product model |
UC500-30GM-IUO-V15 |
UC2000-30GM-IUO-V15 |
|
UC500-30GM-IUR2-V15 |
UC2000-30GM-IUR2-V15 |
|
|
Detection range |
50...500mm |
80...2000mm |
|
Detect dead zones |
0...50mm |
0...80mm |
|
Transducer frequency |
About 380Khz |
About 180Khz |
|
Response time |
Minimum 21ms |
Minimum 65ms |
|
Standard target board |
100mm*100mm |
|
|
Output type |
One current output 4... 20mA |
|
|
One voltage output is 0-10V |
||
|
Operating voltage |
10-30VDC ripple 10% |
|
|
Power consumption |
≤900mw |
|
|
Repeatability |
±0.1% of full-scale value |
|
|
Range adjustment |
The farthest and closest ranges are adjusted by the adjustment line |
|
|
Degree of protection |
IP65 |
|
|
Connection method |
V15 (5-pin) M12 cable/2m PVC cable |
|
|
LED green light |
Always-on: powered on Flashing: The target is detected in the set state |
|
|
LED yellow light |
The switch status indicator flashes The target has been detected in the set state |
|
|
LED red light |
Solid red light: Error Flashing red light: No target detected in the set state |
|