ESMTUF2000F External clamp type acid-base solution non-contact measurement ultrasonic flowmeter

The external clip type ultrasonic flowmeter is composed of a main body and an external clip type sensor. Simply attach the clip-on sensor to the surface of the pipe to complete the flow measurement of various liquids. Compared with the traditional flow meter, it does not need to cut off the tube, and the installation is convenient and fast, realizing the non-destructive installation.

    Working Principle

    The time-difference method is usually used, where an external clamp-on sensor emits and receives ultrasonic waves, measures the difference in propagation time of the ultrasonic waves in the fluid in the downstream and upstream directions, and then calculates the fluid flow velocity. Combined with parameters such as the pipe's cross-sectional area, the flow rate can be determined.

    Product Features

    1.  No need to break the pipeline or stop production;
    2.  the sensor does not come into contact with the measured medium 
    3.  causes no pressure loss.

    Product detail

    ESMTUF2000F-9-1ESMTDS100F-p-1

    Technical Specifications

    Items

    Specifications

    Main unit

    Accuracy

    Better than ±1%

    Repeatability

    Better than 0.2%

    Principle

    Transit-time measuring principle

    Measurement

    Period

    500ms

    Display

    LCD with backlight, display accumulated flow/heat, instantaneous flow/heat, velocity, time etc.

    Output

    Analogue output: 4-20mA or 0-20mA current output. Impedance 0∼1kW. Accuracy 0.1%.

    OCT output: Frequency signal (1~9999HZ)

    Relay output: over 20 source signal (no signal, reverse flow etc.)

    RS485 serial port

     

    Input

    Three analogue input

    Three-wire PT100 resistor input (optional)

    Other functions

    Automatically record the totaliser data of the last 64 days / 64 months / 5 years;

    The power-on time and corresponding flow rate of the last 64 power on and off events. Allow manual or automatic flow loss compensation

    The instrument working status of the last 64 days

    pipe

    material

    Steel, stainless steel, cast iron, cement pipe, copper, PVC, aluminum, FRP etc. Liner is allowed

    Size

    15-6000mm

    Straight pipe section

    In the upstream it must be beyond 10D, in the downstream it must be beyond 5D, in the upstream the length must be beyond 30D from the access of the pump. (D stands for pipe diameter)

    Liquid

    Types

    Water, sea water, industrial sewage, acid & alkali liquid, alcohol, beer, all kinds of oils which can transmit ultrasonic single uniform liquid

    Temperature

    Standard: -30C - 90C ,High-temperature:-30C - 160C

    Turbidity

    Less than 10000ppm, with a little bubble

     

    Flow Direction

    Bi-directional measuring, net flow/heat measuring

    Environment

    Temperature

    Main Unit: -30C - 80C

    Transducer: -40℃ -110℃, Temperature transducer: select on enquiry

    Humidity

    Main Unit: 85% RH

    Transducer: water-immersible, water depth less than 3m

    Cable

    Twisted Pair Line, standard length of 20m, can be extended to 500m (not recommended); Contact the manufacturer for longer cable requirement.

    RS-485 interface, transmission distance up to 1000m

    Power Supply

    AC220V or DC24V

    Power Consumption

    Less than 1.5W

    Protocols

    MODBUS, M-BUS, Fuji extended protocol and other factory protocol