High-Frequency 2000mm water tank Ultrasonic level Sensor for UC2000-U9
Working Principle
The ultrasonic proximity switch's transmitter emits high-frequency ultrasonic waves. When these waves encounter an object, they are reflected back. The receiver captures the reflected echoes, and by measuring the time it takes for the ultrasonic waves to travel from transmission to reception, and combining this with the propagation speed of ultrasound in air, the distance between the sensor and the object can be calculated. When the distance reaches a preset threshold, the switch outputs the corresponding signal.
Product Features
1.Multiple signal outputs
2.Non-contact detection
3.Strong environmental adaptability
4.Wide detection range
5.Unaffected by material
Product detail


Technical Specifications
|
Product model |
UC500+U9+E4+R2 |
UC2000+U9+E4+R2 |
UC4000+U9+E4+R2 |
|
UC500+U9+E5+R2 |
UC2000+U9+E5+R2 |
UC4000+U9+E5+R2 |
|
|
Detection range |
50...500mm |
80...2000mm |
200...4000mm |
|
Detect dead zones |
0...50mm |
0...80mm |
0...200mm |
|
Transducer frequency |
About 380khz |
About 180khz |
About 85khz |
|
Response time |
About 50ms |
About 150ms |
About 325ms |
|
Switching frequency |
≤10HZ |
≤3.3HZ |
≤1.5HZ |
|
Output type |
E4: NPN NO/NC |
||
|
E5: PNP NO/NC |
|||
|
Operating voltage |
10-30VDC ripple 10% |
||
|
Rated operating current |
200mA short-circuit protection/overload protection |
||
|
Repeatability |
≤0.5% |
||
|
Range adjustment |
The farthest and closest ranges are adjusted by the adjustment line |
||
|
Degree of protection |
IP65 |
||
|
Connection method |
Through the junction box, the cross-sectional area of the wire core ≤ 2.5mm2 |
||
|
LED yellow light |
The switch status indicates that the yellow light is flashing The target is detected in the set state |
||
|
LED red light |
Solid red: Error Flashing red light: No target detected in the set state |
||
|
Product model |
UC500+U9+E6+R2 |
UC2000+U9+E6+R2 |
UC4000+U9+E6+R2 |
|
UC500+U9+E7+R2 |
UC2000+U9+E7+R2 |
UC4000+U9+E7+R2 |
|
|
Detection range |
50...500mm |
80...2000mm |
200...4000mm |
|
Detect dead zones |
0...50mm |
0...80mm |
0...200mm |
|
Transducer frequency |
About 380khz |
About 180khz |
About 85khz |
|
Response time |
About 21ms |
About 65ms |
About 145ms |
|
Switching frequency |
≤7HZ |
≤2.5HZ |
≤1HZ |
|
Output type |
E6:Two ways PNP NO/NC |
||
|
E7:Two ways NPN NO/NC |
|||
|
Operating voltage |
10-30VDC ripple 10% |
||
|
Rated operating current |
200mA short-circuit protection/overload protection |
||
|
Repeatability |
≤0.5% |
||
|
Range adjustment |
The farthest and closest ranges are adjusted by the adjustment line |
||
|
Degree of protection |
IP65 |
||
|
Connection method |
Through the junction box, the cross-sectional area of the wire core ≤ 2.5mm2 |
||
|
LED yellow light |
The switch status indicates that the yellow light is flashing The target is detected in the set state |
||
|
LED red light |
Solid red: Error Flashing red light: No target detected in the set state |
||
|
Product model |
UC500+U9+I+R2 |
UC2000+U9+I+R2 |
UC4000+U9+I+R2 |
|
UC500+U9+U+R2 |
UC2000+U9+U+R2 |
UC4000+U9+U+R2 |
|
|
Detection range |
50...500mm |
80...2000mm |
200...4000mm |
|
Detect dead zones |
0...50mm |
0...80mm |
0...200mm |
|
Transducer frequency |
About 380Khz |
About 180Khz |
About 85Khz |
|
Response time |
Minimum 21ms |
Minimum 65ms |
Minimum 145ms |
|
Standard target board |
100mm*100mm |
||
|
Output type |
I: 4-20mA |
||
|
U:0-10V |
|||
|
Operating voltage |
I:10-30VDC ripple 10% U:15-30VDC ripple 10% |
||
|
power consumption |
≤900mW |
||
|
Repeatability |
±0.1% of full-scale value |
||
|
Range adjustment |
The farthest and closest ranges are adjusted by the adjustment line |
||
|
Degree of protection |
IP65 |
||
|
Connection method |
Through the junction box, the cross-sectional area of the wire core ≤ 2.5mm2 |
||
|
LED green light |
Always-on: powered on Flashing: The target is detected in the set state |
||
|
LED yellow light |
The switch status indicator flashes Set the status to detect a target |
||
|
LED red light |
Solid red light: Error Flashing red light: No target detected in the set state |
||