UC500-L2 ultrasonic detection Proximity sensor switch for assembly line counting
Working Principle
The ultrasonic proximity switch's transmitter emits high-frequency ultrasonic waves. When these waves encounter an object, they are reflected back. The receiver captures the reflected echoes, and by measuring the time it takes for the ultrasonic waves to travel from transmission to reception, and combining this with the propagation speed of ultrasound in air, the distance between the sensor and the object can be calculated. When the distance reaches a preset threshold, the switch outputs the corresponding signal.
Product Features
1. Rotatable / Bidirectional Probe
The probe can rotate 360° and be installed in both directions, flexibly adapting to tight spaces and different installation angles.
2. Omnidirectional Status Indication
Multicolor LEDs (green/yellow/red) allow viewing of operation/detection/fault status from any angle.
3. Highly Programmable Parameters
Switch points, window mode, normally open/normally closed, and sound cone width (wide/narrow) can all be set.
Supports multi-sensor synchronization to avoid ultrasonic interference.
Can be configured via a programming adapter or serial port.
4. Stable and Reliable Industrial Design
Built-in temperature compensation reduces the impact of temperature drift.
Resistant to dust, humidity, and light oil; unaffected by color or transparency.
Quick-install clips make on-site deployment convenient.
5. Flexible Applications
Suitable for: material/liquid level monitoring, AGV obstacle avoidance, assembly line positioning, packaging verification, and distance measurement.
application scenarios
Material level / liquid level monitoring, AGV obstacle avoidance, assembly line positioning, packaging position detection, distance measurement.
Product detail


Technical Specifications
|
Product model |
UC500-L2-E4-V15 |
UC2000-L2-E4-V15 |
UC4000-L2-E4-V15 |
|
UC500-L2-E5-V15 |
UC2000-L2-E5-V15 |
UC4000-L2-E5-V15 |
|
|
Detection range |
50...500mm |
80...2000mm |
200...4000mm |
|
Detect dead zones |
0...50mm |
0...80mm |
0...200mm |
|
Transducer frequency |
About 380khz |
About 180khz |
About 85khz |
|
Response time |
About 50ms |
About 150ms |
About 325ms |
|
Switching frequency |
≤10Hz |
≤3.3Hz |
≤1.5Hz |
|
Output type |
E4 NPN NO/NC |
||
|
E5 PNP NO/NC |
|||
|
Operating voltage |
10-30VDC ripple 10% |
||
|
Rated operating current |
200mA short-circuit protection/overload protection |
||
|
Repeatability |
≤0.5% |
||
|
Range adjustment |
The farthest and closest ranges are adjusted by the adjustment line |
||
|
Degree of protection |
IP65 |
||
|
Connection method |
V15 (5-pin) M12 cable/2m PVC cable |
||
|
LED yellow light |
The switch status indicates that the yellow light is flashing The target is detected in the set state |
||
|
LED red light |
Solid red light: Error Flashing red light: No target detected in the set state |
||
|
Product model |
UC500-L2-E6-V15 |
UC2000-L2-E6-V15 |
UC4000-L2-E6-V15 |
|
UC500-L2-E7-V15 |
UC2000-L2-E7-V15 |
UC4000-L2-E7-V15 |
|
|
Detection range |
50...500mm |
80...2000mm |
200...4000mm |
|
Detect dead zones |
0...50mm |
0...80mm |
0...200mm |
|
Transducer frequency |
About 380khz |
About 180khz |
About 85khz |
|
Response time |
Minimum 21ms |
Minimum 65ms |
Minimum 145ms |
|
Switching frequency |
≤7Hz |
≤2.5Hz |
≤1Hz |
|
Output type |
E6: Two ways PNP NO/NC |
||
|
E7: Two ways NPN NO/NC |
|||
|
Operating voltage |
10-30VDC ripple 10% |
||
|
Rated operating current |
200mA short-circuit protection/overload protection |
||
|
Repeatability |
≤0.5% |
||
|
Range adjustment |
The farthest and closest ranges are adjusted by the adjustment line |
||
|
Degree of protection |
IP65 |
||
|
Connection method |
V15 (5-pin) M12 cable/2m PVC cable |
||
|
LED yellow light |
The switch status indicates that the yellow light is flashing The target is detected in the set state |
||
|
LED red light |
Solid red light: Error Flashing red light: No target detected in the set state |
||
|
Product model |
UC500-L2-I-V15 |
UC2000-L2-I-V15 |
UC4000-L2-I-V15 |
|
UC500-L2-U-V15 |
UC2000-L2-U-V15 |
UC4000-L2-U-V15 |
|
|
Detection range |
50...500mm |
80...2000mm |
200...4000mm |
|
Detect dead zones |
0...50mm |
0...80mm |
0...200mm |
|
Transducer frequency |
About 380khz |
About 180khz |
About 85khz |
|
Response time |
Minimum 21ms |
Minimum 65ms |
Minimum 145ms |
|
Standard target board |
100mm*100mm |
||
|
Output type |
I: 4... 20mA |
||
|
U:0-10V |
|||
|
Operating voltage |
10-30VDC ripple 10% |
||
|
power consumption |
≤900mW |
||
|
Repeatability |
±0.1% of full-scale value |
||
|
Range adjustment |
The farthest and closest ranges are adjusted by the adjustment line |
||
|
Degree of protection |
IP65 |
||
|
Connection method |
V15 (5-pin) M12 cable/2m PVC cable |
||
|
LED green light |
Always-on: powered on Flashing: The target is detected in the set state |
||
|
LED yellow light |
The switch status indicator flashes The target is detected in the set state |
||
|
LED red light |
Solid red: Error Flashing red light: No target detected in the set state |
||