high quality waterproof ultrasonic proximity sensor Module for UC500-F42
Working Principle
The ultrasonic proximity switch's transmitter emits high-frequency ultrasonic waves. When these waves encounter an object, they are reflected back. The receiver captures the reflected echoes, and by measuring the time it takes for the ultrasonic waves to travel from transmission to reception, and combining this with the propagation speed of ultrasound in air, the distance between the sensor and the object can be calculated. When the distance reaches a preset threshold, the switch outputs the corresponding signal.
Product Features
1. Non-contact measurement, unaffected by the color or material of the target object;
2. Wide measurement range: commonly 300mm~5000mm, with some models reaching up to 6m;
3. High protection level: mostly IP65/IP67, suitable for humid, dusty, and other industrial environments;
4. Supports temperature compensation and interference suppression, ensuring strong measurement stability;
5. Flexible signal output: supports NPN/PNP switching, 4-20mA analog output, or IO-Link digital communication.
APPLICATION SCENARIOS
1. Warehousing and logistics: cargo height/position detection, stacker positioning;
2. Process industry: storage tank liquid level, silo material level monitoring;
3. Automated production line: workpiece in-position detection, obstacle avoidance;
4. Construction machinery: vehicle/equipment distance warning and collision prevention
Product detail


Technical Specifications
|
Product model |
UC500-F42-E4-V15 |
UC2000-F42-E4-V15 |
UC4000-F42-E4-V15 |
|
UC500-F42-E5-V15 |
UC2000-F42-E5-V15 |
UC4000-F42-E5-V15 |
|
|
Detection range |
50...500mm |
80...2000mm |
200...4000mm |
|
Detect dead zones |
0...50mm |
0...80mm |
0...200mm |
|
Transducer frequency |
About 380KHZ |
About 180KHZ |
About 85KHZ |
|
Response time |
About 50ms |
About 150ms |
About 325ms |
|
Switching frequency |
≤10HZ |
≤3.3HZ |
≤1.5HZ |
|
Output type |
E4 NPN NO/NC |
||
|
E5 PNP NO/NC |
|||
|
Operating voltage |
10-30VDC ripple 10% |
||
|
Rated operating current |
200mA short-circuit protection/overload protection |
||
|
Repeatability |
≤0.5% |
||
|
Range adjustment |
The farthest and closest ranges are adjusted by the adjustment line |
||
|
Degree of protection |
IP65 |
||
|
Connection method |
V15 (5-pin) M12 cable/2m PVC cable |
||
|
LED yellow light |
The switch status indicates that the yellow light flashes and the target is detected in the set state |
||
|
LED red light |
Solid red: Error Flashing red light: No target detected in the set state |
||
|
Product model |
UC500-F42-E6-V15 |
UC2000-F42-E6-V15 |
UC4000-F42-E6-V15 |
|
UC500-F42-E7-V15 |
UC2000-F42-E7-V15 |
UC4000-F42-E7-V15 |
|
|
Detection range |
50...500mm |
80...2000mm |
200...4000mm |
|
Detect dead zones |
0...50mm |
0...80mm |
0...200mm |
|
Transducer frequency |
About 380KHZ |
About 180KHZ |
About 85KHZ |
|
Response time |
About 21ms |
About 65ms |
About 145ms |
|
Switching frequency |
≤7HZ |
≤2.5HZ |
≤1HZ |
|
Output type |
E6:Two ways PNP NO/NC |
||
|
E7:Two ways NPN NO/NC |
|||
|
Operating voltage |
10-30VDC ripple 10% |
||
|
Rated operating current |
200mA short-circuit protection/overload protection |
||
|
Repeatability |
≤0.5% |
||
|
Range adjustment |
The farthest and closest ranges are adjusted by the adjustment line |
||
|
Degree of protection |
IP65 |
||
|
Connection method |
V15 (5-pin) M12 cable/2m PVC cable |
||
|
LED yellow light |
The switch status indicates that the yellow light flashes and the target is detected in the set state |
||
|
LED red light |
Solid red: Error Flashing red light: No target detected in the set state |
||
|
Product model |
UC500-F42-I-V15 |
UC2000-F42-I-V15 |
UC4000-F42-I-V15 |
|
UC500-F42-U-V15 |
UC2000-F42-U-V15 |
UC4000-F42-U-V15 |
|
|
Detection range |
50...500mm |
80...2000mm |
200...4000mm |
|
Detect dead zones |
0...50mm |
0...80mm |
0...200mm |
|
Transducer frequency |
About 380KHZ |
About 180KHZ |
About 85KHZ |
|
Response time |
About 21ms |
About 65ms |
About 145ms |
|
Standard target board |
100mm*100mm |
||
|
Output type |
I:4-20mA |
||
|
U:0-10V |
|||
|
Operating voltage |
10-30VDC ripple 10% |
||
|
Rated operating current |
200mA short-circuit protection/overload protection |
||
|
Repeatability |
≤0.5% |
||
|
Range adjustment |
The farthest and closest ranges are adjusted by the adjustment line |
||
|
Degree of protection |
IP65 |
||
|
Connection method |
V15 (5-pin) M12 cable/2m PVC cable |
||
|
LED yellow light |
The switch status indicates that the yellow light flashes and the target is detected in the set state |
||
|
LED red light |
Solid red: Error Flashing red light: No target detected in the set state |
||