Low price ESMFS High and Low Voltage Waterproof Float Level Switch Sensor for sewage treatment plants, water conservancy projects, and drainage systems

The ESMFS waterproof stainless steel float switch is a liquid level control device based on the principles of buoyancy and magnetic coupling. Its body is made of stainless steel and it is equipped with a waterproof junction box (typically rated IP65 or above), suitable for humid, corrosive, or environments requiring waterproof and dustproof protection in both industrial and residential settings.
Main applications include:
1. Industrial Sector
Liquid level monitoring and control: Provides liquid level alarms, remote signal transmission, and pump/valve start-stop control in storage tanks, water tanks, oil tanks, chemical equipment, and similar scenarios.
Special environment adaptation: Suitable for corrosive media (e.g., electroplating wastewater, acid or alkaline solutions), high temperature and high pressure tanks (e.g., steam boilers), and hazardous areas with explosive gases.
2. Municipal Construction
Water treatment systems: Automatic liquid level monitoring and alarms in sewage treatment plants, water conservancy projects, and drainage systems.
Public facilities: Liquid level management for underground water tanks and fire-fighting water tanks to prevent overflow or dry running.
3. Residential Sector
Household appliances: Liquid level control in water tanks, pools, washing machines, water heaters, etc., enabling automatic water replenishment and water-saving functions.
Building applications: Liquid level monitoring in building water towers and rooftop water tanks to ensure stable water supply.[eos]

    Working Principle

     The stainless steel float switch mainly consists of a float, a float rod, a switch assembly, and a housing. The float is usually made of 316L stainless steel, hollow inside, and can float on the liquid surface. The float rod connects the float to the switch assembly. When the liquid level changes, the float drives the float rod to move up and down, causing the switch assembly to close or open, thereby controlling the circuit connection or disconnection.

    Product Features

    1.Strong Corrosion Resistance: Made of stainless steel materials such as SUS304 and SUS316, suitable for various corrosive liquid environments, such as chemical raw materials, acid and alkaline solutions, etc.
    2.Good High-Temperature Performance: The all-stainless-steel float switch can withstand temperatures up to 200°C, meeting the requirements for liquid level control in high-temperature liquids.
    3.Simple and Reliable Structure: The structure is simple and easy to assemble, resistant to failure, with strong anti-interference capability and stable operation.
    4. Multi-Point Control: A single device can be set with 1 to 8 switch points to achieve multi-point liquid level control, with each control point customizable according to customer needs.

     mainteenance recommendations


    1. Regular Inspection
    Float status: Check whether the float is intact, without deformation or cracks, ensuring it can move freely and is not stuck by debris.
    Connection wiring: Check whether the wiring is secure, without looseness or breaks, and ensure terminals are tight and free of corrosion.
    Working environment: Ensure the switch is away from strong magnetic field interference sources to avoid affecting magnetic induction accuracy.
    2. Cleaning and Maintenance
    Exterior cleaning: Regularly wipe the float and switch housing to remove dust, dirt, and other impurities; avoid using chemical cleaners or sharp objects.
    Float cleaning: For liquids containing impurities or high viscosity, periodically clean the surface of the float and the internal magnet to prevent adhesion from affecting float performance.
    3. Function Testing
    Manual testing: Test the switch's ON and OFF functions by simulating liquid level changes (e.g., manually moving the float) to ensure it responds correctly.
    Electrical testing: Use a multimeter to measure the switch's open and closed states, ensuring the contacts are good and there are no short circuits or open circuits.
    4. Fault Handling
    Switch does not operate: Check if the float is stuck, the reed switch is damaged, or if wiring is loose; replace faulty components if necessary.
    Unstable signal: Check whether the contacts are oxidized or contaminated with oil; clean the contact surface or replace the switch.
    False triggering: Adjust the installation angle or reduce liquid level fluctuations (e.g., install a buffer device) to prevent the float from mis-triggering due to tilting or shaking.

    Product detail

    ESMFS-FS- (3)ESMFS- (3)ESMFS- (4)

    Technical Specifications

    TYPES

    Low pressure

    high pressure

    Maximum power

    10W

    50W

    Maximum switching voltage

    100VDC

    220VDC

    Maximum switching current

    0.5A

    1.5A

    Minimum collapse voltage

    220VDC

    300VDC

    Maximum load current

    1A

    3A

    Maximum contact resistance

    100mΩ

    100mΩ

    temperature range

    -20~+80

    -20~+80

    Float material

    SUS304/316

    SUS304/316

    Card spring material

    SUS304/316

    SUS304/316

    Wiring Definition

    This is a paragraph

    1. Black, White - Power
    2. Green - Ground
    3. Yellow - Common (COM), Blue - Normally Closed (NC), Red - Normally Open (NO)

    Leave Your Message