inquiry
Leave Your Message
Products Categories
Featured Products

Low price UC2000-L Water level detection ultrasonic sensor for 2000mm range

This square ultrasonic sensor features a teal compact housing design, paired with a black mounting base and a metal quick-connect interface on top, giving it a sturdy and durable appearance suitable for complex industrial environments. The front white ultrasonic transducer surface enables non-contact distance measurement and object detection, unaffected by target color or transparency, offering high accuracy and strong stability. The product has an IP65/IP67 protection rating, effectively resisting dust, moisture, and light oil contamination. It supports analog (4-20mA/0-10V) or PNP/NPN switch outputs, allowing seamless integration with mainstream PLC control systems. The typical range covers 500mm to 4000mm, with a small blind zone and fast response, widely used in liquid/solid level monitoring, material sorting, AGV collision avoidance, and logistics stacking detection. It is easy to install and provides a reliable measurement and sensing solution in the field of industrial automation.

    Working Principle

     The ultrasonic proximity switch's transmitter emits high-frequency ultrasonic waves. When these waves encounter an object, they are reflected back. The receiver captures the reflected echoes, and by measuring the time it takes for the ultrasonic waves to travel from transmission to reception, and combining this with the propagation speed of ultrasound in air, the distance between the sensor and the object can be calculated. When the distance reaches a preset threshold, the switch outputs the corresponding signal.

    Product Features

    1. Strong anti-interference capability: The enclosure protection level is usually IP65/IP67, suitable for industrial environments with dust, humidity, and light oil contamination.

    2. Multiple output types: Supports analog (4-20mA/0-10V) and PNP/NPN switch outputs, compatible with mainstream PLC control systems.

    3. Wide range coverage: Common ranges are 500mm~4000mm (for example, UC2000 has a 2000mm range, UC4000 has a 4000mm range), with minimal blind zones.

    4. Easy installation: Comes with a mounting bracket for quick attachment to equipment or stands, supports side/front installation, adaptable to various scenarios.

     application scenarios

    1. Industrial Automation:
    Liquid Level Detection: Used for monitoring the liquid level in chemical storage tanks and water treatment tanks (non-contact, corrosion-resistant).
    Object Counting and Positioning: Detection of products on conveyor belts, positioning for robotic arm grabbing.
    Collision Protection: Obstacle detection for automated guided vehicles (AGV) and mobile robots.

    2. Automotive Electronics:
    Parking Radar: Detects the distance of obstacles in front of and behind the vehicle, providing sound or image warnings.
    Blind Spot Detection: Used in some vehicle models for detecting vehicles on the side and rear.

    3. Consumer Electronics and Smart Home:
    Robotic Vacuums: Obstacle avoidance and wall-following.
    Drones: Altitude hold (altimeter) and downward obstacle avoidance.
    Medical Equipment: Some non-destructive testing and imaging devices.

    Product detail

    UC500-L2- (1)UB500-18GM75- (2)ESMUS07- (3)

    Technical Specifications

    Product model

    UC500-L2-E4-V15

    UC2000-L2-E4-V15

    UC4000-L2-E4-V15

    UC500-L2-E5-V15

    UC2000-L2-E5-V15

    UC4000-L2-E5-V15

    Detection range

    50...500mm

    80...2000mm

    200...4000mm

    Detect dead zones

    0...50mm

    0...80mm

    0...200mm

    Transducer frequency

    About 380khz

    About 180khz

    About 85khz

    Response time

    About 50ms

    About 150ms

    About 325ms

    Switching frequency

    ≤10Hz

    ≤3.3Hz

    ≤1.5Hz

    Output type

    E4 NPN NO/NC

    E5 PNP NO/NC

    Operating voltage

    10-30VDC ripple 10%

    Rated operating current

    200mA short-circuit protection/overload protection

    Repeatability

    ≤0.5%

    Range adjustment

    The farthest and closest ranges are adjusted by the adjustment line

    Degree of protection

    IP65

    Connection method

    V15 (5-pin) M12 cable/2m PVC cable

    LED yellow light

    The switch status indicates that the yellow light is flashing  

    The target is detected in the set state

    LED red light

    Solid red light: Error      Flashing red light: No target detected in the set state

    Product model

    UC500-L2-E6-V15

    UC2000-L2-E6-V15

    UC4000-L2-E6-V15

    UC500-L2-E7-V15

    UC2000-L2-E7-V15

    UC4000-L2-E7-V15

    Detection range

    50...500mm

    80...2000mm

    200...4000mm

    Detect dead zones

    0...50mm

    0...80mm

    0...200mm

    Transducer frequency

    About 380khz

    About 180khz

    About 85khz

    Response time

    Minimum 21ms

    Minimum 65ms

    Minimum 145ms

    Switching frequency

    ≤7Hz

    ≤2.5Hz

    ≤1Hz

    Output type

    E6: Two ways PNP NO/NC

    E7: Two ways NPN NO/NC

    Operating voltage

    10-30VDC ripple 10%

    Rated operating current

    200mA short-circuit protection/overload protection

    Repeatability

    ≤0.5%

    Range adjustment

    The farthest and closest ranges are adjusted by the adjustment line

    Degree of protection

    IP65

    Connection method

    V15 (5-pin) M12 cable/2m PVC cable

    LED yellow light

    The switch status indicates that the yellow light is flashing  

    The target is detected in the set state

    LED red light

    Solid red light: Error      Flashing red light: No target detected in the set state

    Product model

    UC500-L2-I-V15

    UC2000-L2-I-V15

    UC4000-L2-I-V15

    UC500-L2-U-V15

    UC2000-L2-U-V15

    UC4000-L2-U-V15

    Detection range

    50...500mm

    80...2000mm

    200...4000mm

    Detect dead zones

    0...50mm

    0...80mm

    0...200mm

    Transducer frequency

    About 380khz

    About 180khz

    About 85khz

    Response time

    Minimum 21ms

    Minimum 65ms

    Minimum 145ms

    Standard target board

    100mm*100mm

    Output type

    I: 4... 20mA

    U:0-10V

    Operating voltage

    10-30VDC ripple 10%

    power consumption

    ≤900mW

    Repeatability

    ±0.1% of full-scale value

    Range adjustment

    The farthest and closest ranges are adjusted by the adjustment line

    Degree of protection

    IP65

    Connection method

    V15 (5-pin) M12 cable/2m PVC cable

    LED green light

    Always-on: powered on   Flashing: The target is detected in the set state

    LED yellow light

    The switch status indicator flashes  

    The target is detected in the set state

    LED red light

    Solid red: Error    

    Flashing red light: No target detected in the set state

    Wiring Definition

    This is a paragraph

    1. Black, White - Power
    2. Green - Ground
    3. Yellow - Common (COM), Blue - Normally Closed (NC), Red - Normally Open (NO)

    Leave Your Message