Low price UC2000-L Water level detection ultrasonic sensor for 2000mm range
Working Principle
The ultrasonic proximity switch's transmitter emits high-frequency ultrasonic waves. When these waves encounter an object, they are reflected back. The receiver captures the reflected echoes, and by measuring the time it takes for the ultrasonic waves to travel from transmission to reception, and combining this with the propagation speed of ultrasound in air, the distance between the sensor and the object can be calculated. When the distance reaches a preset threshold, the switch outputs the corresponding signal.
Product Features
1. Strong anti-interference capability: The enclosure protection level is usually IP65/IP67, suitable for industrial environments with dust, humidity, and light oil contamination.
2. Multiple output types: Supports analog (4-20mA/0-10V) and PNP/NPN switch outputs, compatible with mainstream PLC control systems.
3. Wide range coverage: Common ranges are 500mm~4000mm (for example, UC2000 has a 2000mm range, UC4000 has a 4000mm range), with minimal blind zones.
4. Easy installation: Comes with a mounting bracket for quick attachment to equipment or stands, supports side/front installation, adaptable to various scenarios.
application scenarios
1. Industrial Automation:
Liquid Level Detection: Used for monitoring the liquid level in chemical storage tanks and water treatment tanks (non-contact, corrosion-resistant).
Object Counting and Positioning: Detection of products on conveyor belts, positioning for robotic arm grabbing.
Collision Protection: Obstacle detection for automated guided vehicles (AGV) and mobile robots.
2. Automotive Electronics:
Parking Radar: Detects the distance of obstacles in front of and behind the vehicle, providing sound or image warnings.
Blind Spot Detection: Used in some vehicle models for detecting vehicles on the side and rear.
3. Consumer Electronics and Smart Home:
Robotic Vacuums: Obstacle avoidance and wall-following.
Drones: Altitude hold (altimeter) and downward obstacle avoidance.
Medical Equipment: Some non-destructive testing and imaging devices.
Product detail


Technical Specifications
|
Product model |
UC500-L2-E4-V15 |
UC2000-L2-E4-V15 |
UC4000-L2-E4-V15 |
|
UC500-L2-E5-V15 |
UC2000-L2-E5-V15 |
UC4000-L2-E5-V15 |
|
|
Detection range |
50...500mm |
80...2000mm |
200...4000mm |
|
Detect dead zones |
0...50mm |
0...80mm |
0...200mm |
|
Transducer frequency |
About 380khz |
About 180khz |
About 85khz |
|
Response time |
About 50ms |
About 150ms |
About 325ms |
|
Switching frequency |
≤10Hz |
≤3.3Hz |
≤1.5Hz |
|
Output type |
E4 NPN NO/NC |
||
|
E5 PNP NO/NC |
|||
|
Operating voltage |
10-30VDC ripple 10% |
||
|
Rated operating current |
200mA short-circuit protection/overload protection |
||
|
Repeatability |
≤0.5% |
||
|
Range adjustment |
The farthest and closest ranges are adjusted by the adjustment line |
||
|
Degree of protection |
IP65 |
||
|
Connection method |
V15 (5-pin) M12 cable/2m PVC cable |
||
|
LED yellow light |
The switch status indicates that the yellow light is flashing The target is detected in the set state |
||
|
LED red light |
Solid red light: Error Flashing red light: No target detected in the set state |
||
|
Product model |
UC500-L2-E6-V15 |
UC2000-L2-E6-V15 |
UC4000-L2-E6-V15 |
|
UC500-L2-E7-V15 |
UC2000-L2-E7-V15 |
UC4000-L2-E7-V15 |
|
|
Detection range |
50...500mm |
80...2000mm |
200...4000mm |
|
Detect dead zones |
0...50mm |
0...80mm |
0...200mm |
|
Transducer frequency |
About 380khz |
About 180khz |
About 85khz |
|
Response time |
Minimum 21ms |
Minimum 65ms |
Minimum 145ms |
|
Switching frequency |
≤7Hz |
≤2.5Hz |
≤1Hz |
|
Output type |
E6: Two ways PNP NO/NC |
||
|
E7: Two ways NPN NO/NC |
|||
|
Operating voltage |
10-30VDC ripple 10% |
||
|
Rated operating current |
200mA short-circuit protection/overload protection |
||
|
Repeatability |
≤0.5% |
||
|
Range adjustment |
The farthest and closest ranges are adjusted by the adjustment line |
||
|
Degree of protection |
IP65 |
||
|
Connection method |
V15 (5-pin) M12 cable/2m PVC cable |
||
|
LED yellow light |
The switch status indicates that the yellow light is flashing The target is detected in the set state |
||
|
LED red light |
Solid red light: Error Flashing red light: No target detected in the set state |
||
|
Product model |
UC500-L2-I-V15 |
UC2000-L2-I-V15 |
UC4000-L2-I-V15 |
|
UC500-L2-U-V15 |
UC2000-L2-U-V15 |
UC4000-L2-U-V15 |
|
|
Detection range |
50...500mm |
80...2000mm |
200...4000mm |
|
Detect dead zones |
0...50mm |
0...80mm |
0...200mm |
|
Transducer frequency |
About 380khz |
About 180khz |
About 85khz |
|
Response time |
Minimum 21ms |
Minimum 65ms |
Minimum 145ms |
|
Standard target board |
100mm*100mm |
||
|
Output type |
I: 4... 20mA |
||
|
U:0-10V |
|||
|
Operating voltage |
10-30VDC ripple 10% |
||
|
power consumption |
≤900mW |
||
|
Repeatability |
±0.1% of full-scale value |
||
|
Range adjustment |
The farthest and closest ranges are adjusted by the adjustment line |
||
|
Degree of protection |
IP65 |
||
|
Connection method |
V15 (5-pin) M12 cable/2m PVC cable |
||
|
LED green light |
Always-on: powered on Flashing: The target is detected in the set state |
||
|
LED yellow light |
The switch status indicator flashes The target is detected in the set state |
||
|
LED red light |
Solid red: Error Flashing red light: No target detected in the set state |
||