PNP/NPN/4-20mA/0-10V output UC500-F54 Wide Detecting Range Proximity Sensor Switch
Working Principle
The ultrasonic proximity switch's transmitter emits high-frequency ultrasonic waves. When these waves encounter an object, they are reflected back. The receiver captures the reflected echoes, and by measuring the time it takes for the ultrasonic waves to travel from transmission to reception, and combining this with the propagation speed of ultrasound in air, the distance between the sensor and the object can be calculated. When the distance reaches a preset threshold, the switch outputs the corresponding signal.
Product Features
1.Multiple signal outputs
2.Non-contact detection
3.Strong environmental adaptability
4.Wide detection range
5.Unaffected by material
Product detail


Technical Specifications
|
Product model |
UC500-F54-E4-V15 |
UC2000-F54-E4-V15 |
UC500-F54-E6-V15 |
UC2000-F54-E6-V15 |
|
UC500-F54-E5-V15 |
UC2000-F54-E5-V15 |
UC500-F54-E7-V15 |
UC2000-F54-E7-V15 |
|
|
Detection range |
50...500mm |
80...2000mm |
50...500mm |
80...2000mm |
|
Detect dead zones |
0...50mm |
0...80mm |
0...50mm |
0...80mm |
|
Transducer frequency |
About 380khz |
About 180khz |
About 380khz |
About 180khz |
|
Response time |
About 50ms |
About 150ms |
About 50ms |
About 150ms |
|
Switching frequency |
≤8HZ |
≤2.7HZ |
≤8HZ |
≤2.7HZ |
|
Output type |
E4: NPN NO/NC |
E6:Two ways PNP NO/NC |
||
|
E5: PNP NO/NC |
E7:Two ways NPN NO/NC |
|||
|
Rated operating current |
200mA short-circuit protection/overload protection |
2*100mA short-circuit protection/overload protection |
||
|
Repeatability |
≤0.5% |
≤0.1% |
||
|
Operating voltage |
10-30VDC ripple 10% |
|||
|
Range adjustment |
The farthest and closest ranges are adjusted by the adjustment line |
|||
|
Degree of protection |
IP65 |
|||
|
Connection method |
V15 (5-pin) M12 cable/2m PVC cable |
|||
|
LED green light |
Always-on: powered on Flashing: The target is detected in the set state |
|||
|
LED yellow light |
Solid: Switch status output Blinking: Set |
|||
|
LED red light |
Working Status: Error Setting Status: No target detected under Settings |
|||
|
Product model |
UC500-F54-I-V15 |
UC2000-F54-I-V15 |
|
UC500-F54-U-V15 |
UC2000-F54-U-V15 |
|
|
Detection range |
50...500mm |
80...2000m |
|
Detect dead zones |
0...50mm |
0...80mm |
|
Transducer frequency |
About 380khz |
About 175khz |
|
Response time |
About 50ms |
About 150ms |
|
Standard target board |
100mm*100mm |
|
|
Output type |
I:4-20mA Short circuit/overload protection |
|
|
U:0-10V |
||
|
Operating voltage |
I:10-30VDC ripple 10% U:15-30VDC ripple 10% |
|
|
No-load current |
I≤45mA U≤50mA |
|
|
Repeatability |
≤0.1% |
|
|
Range adjustment |
The farthest and closest ranges are adjusted by the adjustment line |
|
|
Degree of protection |
IP65 |
|
|
Connection method |
V15 (5-pin) M12 cable/2m PVC cable |
|
|
LED yellow light |
The switch status indicator flashes The target has been detected in the set state |
|
|
LED red light |
Solid red: Error Flashing red light: No target detected in the set state |
|