inquiry
Leave Your Message
Products Categories
Featured Products

UB1000-Q30 Non-Contact Industrial Liquid Level Detection ultrasonic sensor

The UB1000-Q30 is an industrial-grade square ultrasonic proximity switch, with a detection range of 70–1000mm and a blind zone of 0–70mm, compatible with 10–30VDC power supply. It uses the principle of ultrasonic time-of-flight for non-contact measurement and is not affected by color, dust, or mist. It supports switch output (NPN/PNP) and 0–10V analog output, featuring TEACH programming and LED status indication. It has IP65/IP67 protection, an M12 connector, a response time of approximately 65–125ms, and a repeatability of ±0.1% FS. It is suitable for liquid level, material level, transparent object detection, and AGV obstacle avoidance, and is compatible with PLCs and automation systems.

    Working Principle

    The ultrasonic proximity switch's transmitter emits high-frequency ultrasonic waves. When these waves encounter an object, they are reflected back. The receiver captures the reflected echoes, and by measuring the time it takes for the ultrasonic waves to travel from transmission to reception, and combining this with the propagation speed of ultrasound in air, the distance between the sensor and the object can be calculated. When the distance reaches a preset threshold, the switch outputs the corresponding signal.

    Product Features

    1.Multiple signal outputs  
    2.Non-contact detection  
    3.Strong environmental adaptability  
    4.Wide detection range  
    5.Unaffected by material

     application  scenarios

    1. Material level / liquid level monitoring: hoppers, small storage tanks, shallow troughs
    2. Object in position / presence detection: assembly lines, assembly stations, mechanical positioning
    3. AGV / cart collision prevention: short-distance obstacle warning
    4. Transparent object detection: PET bottles, glass, acrylic

    Product detail

    UB500-Q30- (1)UB500-18GM75- (2)ESMUS07- (3)

    Technical Specifications

    Product model

    UB500-Q30-E4-V15

    UB1000-Q30-E4-V15

    UB500-Q30-E6-V15

    UB1000-Q30-E6-V15

     

    UB500-Q30-E5-V15

    UB1000-Q30-E5-V15

    UB500-Q30-E7-V15

    UB1000-Q30-E7-V15

    Detection range

    50...500mm

    70...1000mm

    50...500mm

    70...1000mm

    Detect dead zones

    0...50mm

    0...70mm

    0...50mm

    0...70mm

    Transducer frequency

    About 380khz

    About 205khz

    About 380khz

    About 205khz

    Response time

    About 50ms

    About 125ms

    About 50ms

    About 125ms

    Switching frequency

    ≤8hz

    ≤3hz

    ≤8hz

    ≤3hz

    Output type

    E4: NPN NO/NC

    E6: Two ways PNP NO/NC

     

    E5: PNP NO/NC

    E7: Two ways NPN NO/NC

    Rated operating current

    200mA short-circuit protection/overload protection

    2*100mA short-circuit protection/overload protection

    Operating voltage

    10-30VDC ripple 10%

    Repeatability

    ≤1%

    Range adjustment

    The farthest and closest ranges are adjusted by the adjustment line

    Degree of protection

    IP65

    Connection method

    V15 (5-pin) M12 cable/2m PVC cable

    LED yellow light

    The switch status indicates that the yellow light flashes and the target is detected in the set state

    LED red light

    Solid red: Error   

    Flashing red light: No target detected in the set state

    Product model

    UB500-Q30-I-V15

    UB1000-Q30-I-V15

    UB500-Q30-U-V15

    UB1000-Q30-U-V15

    Detection range

    50...500mm

    70...1000mm

    Detect dead zones

    0...50mm

    0...70mm

    Transducer frequency

    About 380KHZ

    About 205KHZ

    Response time

    About 50ms

    About 125ms

    Standard target board

    100mm*100mm

    Output type

    I: 4-20mA short circuit/overload protection

    U:0-10V

    Operating voltage

    I: 10-30VDC ripple 10%   U: 15-30VDC ripple 10%

    No-load current

    I:≤45mA              U:≤50mA

    Repeatability

    ±1.5% of full-scale value

    Range adjustment

    The farthest and closest ranges are adjusted by the adjustment line

    Degree of protection

    IP65

    Connection method

    V15 (5-pin) M12 cable/2m PVC cable

    LED yellow light

    The switch status indicator flashes The target has been detected in the set state

    LED red light

    Solid red light: Error   Flashing red light: No target detected in the set state

    Wiring Definition

    This is a paragraph

    1. Black, White - Power
    2. Green - Ground
    3. Yellow - Common (COM), Blue - Normally Closed (NC), Red - Normally Open (NO)

    Leave Your Message