UB300-18GM40 Non-contact Detection ultrasonic proximity switch sensor for industrial automation
Working Principle
The ultrasonic proximity sensor has a built-in ultrasonic transducer. The transducer emits high-frequency ultrasonic pulses, which travel through the air. When the sound waves encounter an object, part of the waves is reflected back, and the transducer receives the reflected echo. The sensor calculates the distance between itself and the object by measuring the time interval from emission to reception of the echo, combined with the speed of sound in the air. When an object enters the preset detection range, the sensor outputs the corresponding signal, triggering a switch action or providing distance data.
Product Features
1.5 different output functions can be set
2.Selectable sound lobe width
3. Program input
4.Synchronization options
5.Deactivation option
6.Temperature compensation
7.Very small unusable area
Product detail


Technical Specifications
|
Product model |
UB300-18GM40-E4- V1 |
UB800-18GM40-E4- V1 |
UB300-18GM40A-E4- V1 |
UB800-18GM40A-E4- V1 |
|
UB300-18GM40-E5- V1 |
UB800-18GM40-E5- V1 |
UB300-18GM40A-E5- V1 |
UB800-18GM40A-E5- V1 |
|
|
Detection range |
50...300mm |
50...800mm |
50...300mm |
50...800mm |
|
Detect dead zones |
0...50mm |
0...50mm |
0...50mm |
0...50mm |
|
Transducer frequency |
About 390kHz |
About 205khz |
About 390khz |
About 205khz |
|
Response time |
About 30ms |
About 100ms |
About 30ms |
About 100ms |
|
Switching frequency |
≤13hz |
≤4hz |
≤13hz |
≤4hz |
|
Output type |
E4 NPN NO/NC |
|||
|
E5 PNP NO/NC |
||||
|
Operating voltage |
10-30VDC ripple 10% |
|||
|
Rated operating current |
200mA short-circuit protection/overload protection |
|||
|
Repeatability |
≤1% |
|||
|
Range adjustment |
The farthest and closest ranges are adjusted by the adjustment line |
|||
|
Degree of protection |
IP65 |
|||
|
Connection method |
V1 (4-pin) M12 cable/2m PVC cable |
|||
|
LED yellow light |
The switch status indicates that the yellow light is flashing The target is detected in the set state |
|||
|
LED red light |
Solid red light: Error Flashing red light: No target detected in the set state |
|||