UB4000-30GM 200-4000mm range Ultrasonic Sensor Distance Sensing Proximity Switch
Working Principle
The ultrasonic proximity switch's transmitter emits high-frequency ultrasonic waves. When these waves encounter an object, they are reflected back. The receiver captures the reflected echoes, and by measuring the time it takes for the ultrasonic waves to travel from transmission to reception, and combining this with the propagation speed of ultrasound in air, the distance between the sensor and the object can be calculated. When the distance reaches a preset threshold, the switch outputs the corresponding signal.
Product Features
1.M30 Installation
2.Multiple signal outputs
3.Non-contact detection
4.Strong environmental adaptability
5.Wide detection range
6.Unaffected by material
APPLICATION SCENARIOS
1. Liquid level detection: Detect the liquid height in water tanks and storage tanks (non-contact, suitable for corrosive liquids).
2. Object presence detection: Detect transparent objects (such as glass bottles, plastic films), reflective objects, or objects with irregular shapes.
3. Distance monitoring: Monitor the position of robotic arms and roll diameter control (such as paper or film rolls).
4. Personnel detection: Detect personnel intrusion in automated production lines.
Product detail


Technical Specifications
|
Product model |
UB4000-30GM-E4-V15 |
UB6000-30GM-E4-V15 |
UB4000-30GM-E6-V15 |
UB6000-30GM-E6-V15 |
|
UB4000-30GM-E5-V15 |
UB6000-30GM-E5-V15 |
UB4000-30GM-E7-V15 |
UB6000-30GM-E7-V15 |
|
|
Detection range |
200...4000mm |
350...6000mm |
200...4000mm |
350...6000mm |
|
Detect dead zones |
0...200mm |
0...350mm |
0...200mm |
0...350mm |
|
Transducer frequency |
About 85KHZ |
About 65KHZ |
About 85KHZ |
About 65KHZ |
|
Response time |
About 325ms |
About 650ms |
Minimum 145ms |
Minimum 285ms |
|
Switching frequency |
≤1.5HZ |
≤0.8HZ |
≤1HZ |
≤0.5HZ |
|
Output type |
E4 NPN NO/NC |
E6: Two ways PNP NO/NC |
||
|
E5 PNP NO/NC |
E7: Two ways NPN NO/NC |
|||
|
Rated operating current |
200mA short-circuit protection/overload protection |
2*100mA short circuit protection/overload protection |
||
|
Repeatability |
≤0.5% |
≤0.1% |
||
|
Operating voltage |
10-30VDC ripple 10% |
|||
|
Range adjustment |
The farthest and closest ranges are adjusted by the adjustment line |
|||
|
Degree of protection |
IP65 |
|||
|
Connection method |
V15 (5-pin) M12 cable/2m PVC cable |
|||
|
LED green light |
Always-on: powered on Flashing: The target is detected in the set state |
|||
|
LED yellow light |
Solid: Switch status output Blinking: Set |
|||
|
LED red light |
Working status: Error occurred Setting state: No target detected |
|||
|
Product model |
UC4000-30GM-IUO-V15 |
UC6000-30GM-IUO-V15 |
|
UC4000-30GM-IUR2-V15 |
UC6000-30GM-IUR2-V15 |
|
|
Detection range |
200...4000mm |
350...6000mm |
|
Detect dead zones |
0...200mm |
0...350mm |
|
Transducer frequency |
About 85KHZ |
About 65KHZ |
|
Response time |
Minimum 145ms |
Minimum 285ms |
|
Standard target board |
100mm*100mm |
|
|
Output type |
One current output 4... 20mA |
|
|
One voltage output is 0-10V |
||
|
Operating voltage |
10-30VDC ripple 10% |
|
|
power consumption |
≤900mv |
|
|
Repeatability |
±0.1% of full-scale value |
|
|
Range adjustment |
The farthest and closest ranges are adjusted by the adjustment line |
|
|
Degree of protection |
IP65 |
|
|
Connection method |
V15 (5-pin) M12 cable/2m PVC cable |
|
|
LED green light |
Always-on: powered on Flashing: The target is detected in the set state |
|
|
LED yellow light |
The switch status indicator flashes The target is detected in the set state |
|
|
LED red light |
Solid red: Error Flashing red light: No target detected in the set state |
|