The UB500-T18 is a compact industrial ultrasonic proximity switch with M18 threads, featuring a detection range of 50–500mm and a blind zone of ≤30mm, operating at 10–30VDC. It uses the ultrasonic time-of-flight principle for non-contact distance measurement, unaffected by object color, transparency, dust, or light, offering high stability. It supports NPN/PNP switch outputs, and the detection distance can be flexibly set via the TEACH button, with an LED status indicator. The housing is made of ABS, IP67 rated, oil-resistant, and anti-interference, suitable for harsh industrial environments. It is widely used for liquid/solid level monitoring, transparent object detection, AGV obstacle avoidance, and automated production line positioning, and can be directly connected to a PLC control system.

    Working Principle

    The ultrasonic proximity switch's transmitter emits high-frequency ultrasonic waves. When these waves encounter an object, they are reflected back. The receiver captures the reflected echoes, and by measuring the time it takes for the ultrasonic waves to travel from transmission to reception, and combining this with the propagation speed of ultrasound in air, the distance between the sensor and the object can be calculated. When the distance reaches a preset threshold, the switch outputs the corresponding signal.

    Principle Briefly Explained:
    Emit ultrasonic waves → Reflect upon hitting an object → Receive the echo → Calculate the time → Determine the distance

    Product Features

    1.Multiple signal outputs  
    2.Non-contact detection  
    3.Strong environmental adaptability  
    4.Wide detection range  
    5.Unaffected by material

     OUTPUT  SELECTION GUIDE

    1. Choose digital output (E4/E5):
    When you only need to know "whether it has arrived": for example, whether a robotic arm has reached its position, whether a package is full, or whether a car door is closed.
    Logic: Only two states, "on/off", respond the fastest, and cost the least.
    2. Choose analog output (I/U):
    When you need to know "how much distance": for example, to calculate the remaining height in a silo in real time, or the real-time distance between an AGV vehicle and obstacles.
    Logic: Outputs continuously varying voltage/current, which the PLC can read as specific values for display or closed-loop control.

    Product detail

    UB500-T18- (1)UB300-18GM40- (2)ESMUS07- (3)

    Technical Specifications

    Product model

    UB500-T18-E4-V15

    UB1000-T18-E4-V15

    UB500-T18-E6-V15

    UB1000-T18-E6-V15

    UB500-T18-E5-V15

    UB1000-T18-E5-V15

    UB500-T18-E7-V15

    UB1000-T18-E7-V15

    Detection range

    50...500mm

    70...1000mm

    50...500mm

    70...1000mm

    Detect dead zones

    0...50mm

    0...70mm

    0...50mm

    0...70mm

    Transducer frequency

    About 380khz

    About 205khz

    About 380khz

    About 205khz

    Response time

    About 50ms

    About 125ms

    About 50ms

    About 205ms

    Switching frequency

    ≤8HZ

    ≤3HZ

    ≤8HZ

    ≤3HZ

    Output type

    E4: NPN NO/NC

    E6:Two ways PNP NO/NC

    E5: PNP NO/NC

    E7:Two ways NPN NO/NC

    Rated operating current

    200mA short-circuit protection/overload protection

    2*100mA short-circuit protection/overload protection

    Repeatability

    ≤1%

    Operating voltage

    10-30VDC ripple 10%

    Range adjustment

    The farthest and closest ranges are adjusted by the adjustment line

    Degree of protection

    IP65

    Connection method

    V15 (5-pin) M12 cable/2m PVC cable

    LED yellow light

    The switch status indicates that the yellow light flashes and the target is detected in the set state

    LED red light

    Solid red: Error     Flashing red light: No target detected in the set state

    Product number

    UB500-T18-I-V15

    UB1000-T18-I-V15

    UB500-T18-U-V15

    UB1000-T18-U-V15

    examination range

    50~500mm

    70~1000mm

    Detection blind zone

    0~50mm

    0~70mm

    Transducer frequency

    About 380khz

    About 205khz

    Response time

    About 50ms

    About 125ms

    Standard target board

    100*100mm

    Output type

    I: 4~20mA short circuit/overload protection

    U:0~10V

    Operating Voltage

    I:10~30VDC    U:15~30VDC

    No-load current

    I:≤45Ma     U:≤50mA

    Repeatability

    Full scale is worth ±1.5%

    Range adjustment

    Adjust the farthest and closest range by adjusting the line

    Protection level

    IP65

    Connection method

    V15 (5 pin) M12 cable / 2 m PVC cable

    LED yellow light

    The switch status indicates that the yellow light is blinking. The target is detected in the set state.

    LED red light

    Steady red light: Error Red flashing: No target detected in the setting state

    Wiring Definition

    This is a paragraph

    1. Black, White - Power
    2. Green - Ground
    3. Yellow - Common (COM), Blue - Normally Closed (NC), Red - Normally Open (NO)