inquiry
Leave Your Message
Products Categories
Featured Products

UC4000-L2 200-4000mm sensing long range Ultrasonic water tank level sensor

The UC4000-L2 is a long-range industrial ultrasonic proximity switch, with a detection distance of 200–4000mm and a blind zone of 0–200mm, powered by 12–30VDC. It uses the time-of-flight principle of sound waves, with built-in temperature compensation, non-contact distance measurement, unaffected by object color, dust, or light, and provides stable readings. It supports PNP/NPN switch outputs, can be TEACH programmed, offers selectable beam width, the sensor head is rotatable in both directions, and the LED status light is visible from all angles. With an IP67 protection rating and M12 connector, it is quick to install and highly resistant to interference. Suitable for long-distance liquid/solid level monitoring, warehouse material detection, AGV obstacle avoidance, and large equipment positioning, it can be reliably integrated into PLC automation systems.

    Working Principle

     The ultrasonic proximity switch's transmitter emits high-frequency ultrasonic waves. When these waves encounter an object, they are reflected back. The receiver captures the reflected echoes, and by measuring the time it takes for the ultrasonic waves to travel from transmission to reception, and combining this with the propagation speed of ultrasound in air, the distance between the sensor and the object can be calculated. When the distance reaches a preset threshold, the switch outputs the corresponding signal.

    Product Features

     1.Multiple signal outputs  
    2.Non-contact detection  
    3.Strong environmental adaptability  
    4.Wide detection range  
    5.Unaffected by material

     APPLICATION SCENARIO

    1. Large Tank / Water Pool Level Monitoring
    Remote non-contact liquid level measurement for water towers, sewage tanks, chemical tanks, and acid/base tanks, unaffected by foam, color, or dust.

    2. Silo / Hopper Material Level Detection
    High-level/low-level alarms and continuous level monitoring for bulk materials such as granules, powders, sawdust, plastic pellets, and sand and gravel.

    3. AGV Carts, Forklifts, and Unmanned Vehicle Obstacle Avoidance
    Long-distance detection of obstacles ahead, enabling deceleration and stop protection, suitable for complex factory environments.

    4. Logistics Sorting and Cargo Height Detection
    Detection of cargo height, full and empty status in automated warehouses, stackers, and conveyor lines.

    5. Roll / Sheet Material Spacing and Positioning Control
    Detection, positioning, and correction control of spacing for paper, films, metal rolls, and sheets.

    6. Construction Machinery / Lifting Equipment Limit Control
    Long-distance position detection and collision protection for cranes, lifting platforms, and overhead traveling cranes.

    7. Timber, Building Material, and Heavy Material Detection
    Detection of presence, in-position verification, and counting for logs, pipes, and profiles.

    Product detail

    UC500-L2- (1)UB500-18GM75- (2)ESMUS07- (3)

    Technical Specifications

    Product model

    UC500-L2-E4-V15

    UC2000-L2-E4-V15

    UC4000-L2-E4-V15

    UC500-L2-E5-V15

    UC2000-L2-E5-V15

    UC4000-L2-E5-V15

    Detection range

    50...500mm

    80...2000mm

    200...4000mm

    Detect dead zones

    0...50mm

    0...80mm

    0...200mm

    Transducer frequency

    About 380khz

    About 180khz

    About 85khz

    Response time

    About 50ms

    About 150ms

    About 325ms

    Switching frequency

    ≤10Hz

    ≤3.3Hz

    ≤1.5Hz

    Output type

    E4 NPN NO/NC

    E5 PNP NO/NC

    Operating voltage

    10-30VDC ripple 10%

    Rated operating current

    200mA short-circuit protection/overload protection

    Repeatability

    ≤0.5%

    Range adjustment

    The farthest and closest ranges are adjusted by the adjustment line

    Degree of protection

    IP65

    Connection method

    V15 (5-pin) M12 cable/2m PVC cable

    LED yellow light

    The switch status indicates that the yellow light is flashing  

    The target is detected in the set state

    LED red light

    Solid red light: Error      Flashing red light: No target detected in the set state

    Product model

    UC500-L2-E6-V15

    UC2000-L2-E6-V15

    UC4000-L2-E6-V15

    UC500-L2-E7-V15

    UC2000-L2-E7-V15

    UC4000-L2-E7-V15

    Detection range

    50...500mm

    80...2000mm

    200...4000mm

    Detect dead zones

    0...50mm

    0...80mm

    0...200mm

    Transducer frequency

    About 380khz

    About 180khz

    About 85khz

    Response time

    Minimum 21ms

    Minimum 65ms

    Minimum 145ms

    Switching frequency

    ≤7Hz

    ≤2.5Hz

    ≤1Hz

    Output type

    E6: Two ways PNP NO/NC

    E7: Two ways NPN NO/NC

    Operating voltage

    10-30VDC ripple 10%

    Rated operating current

    200mA short-circuit protection/overload protection

    Repeatability

    ≤0.5%

    Range adjustment

    The farthest and closest ranges are adjusted by the adjustment line

    Degree of protection

    IP65

    Connection method

    V15 (5-pin) M12 cable/2m PVC cable

    LED yellow light

    The switch status indicates that the yellow light is flashing  

    The target is detected in the set state

    LED red light

    Solid red light: Error      Flashing red light: No target detected in the set state

    Product model

    UC500-L2-I-V15

    UC2000-L2-I-V15

    UC4000-L2-I-V15

    UC500-L2-U-V15

    UC2000-L2-U-V15

    UC4000-L2-U-V15

    Detection range

    50...500mm

    80...2000mm

    200...4000mm

    Detect dead zones

    0...50mm

    0...80mm

    0...200mm

    Transducer frequency

    About 380khz

    About 180khz

    About 85khz

    Response time

    Minimum 21ms

    Minimum 65ms

    Minimum 145ms

    Standard target board

    100mm*100mm

    Output type

    I: 4... 20mA

    U:0-10V

    Operating voltage

    10-30VDC ripple 10%

    power consumption

    ≤900mW

    Repeatability

    ±0.1% of full-scale value

    Range adjustment

    The farthest and closest ranges are adjusted by the adjustment line

    Degree of protection

    IP65

    Connection method

    V15 (5-pin) M12 cable/2m PVC cable

    LED green light

    Always-on: powered on   Flashing: The target is detected in the set state

    LED yellow light

    The switch status indicator flashes  

    The target is detected in the set state

    LED red light

    Solid red: Error    

    Flashing red light: No target detected in the set state

    Wiring Definition

    This is a paragraph

    1. Black, White - Power
    2. Green - Ground
    3. Yellow - Common (COM), Blue - Normally Closed (NC), Red - Normally Open (NO)

    Leave Your Message